operatingTemperature

P3958
predicate

Indicates the range or specific value of temperature within which an entity is designed or allowed to function properly.

All labels observed (22)

Label Occurrences
operatingTemperature canonical 8
operatingTemperatureRange 7
storageTemperature 7

Description generation (PDg)

The one-sentence description above was generated by prompting gpt-5.1 with the predicate name and this instruction.

Instruction
Given a predicate that represents a relationship or action between entities, generate a one-sentence description explaining its meaning.  
# Instructions
Focus on describing the relationship, not the entities themselves. 
# Response Format
Begin the description with \' Indicates...\'
Input
Predicate: operatingTemperature
Generated description
Indicates the range or specific value of temperature within which an entity is designed or allowed to function properly.

Sample triples (45)

Subject Object
Large Hadron Collider about 1.9 K
open-hearth process about 1600 °C
James Webb Space Telescope around 40 Kelvin via predicate surface "designedOperatingTemperature"
Nile tilapia 25–30 °C via predicate surface "optimalTemperatureRange"
Janssen COVID-19 Vaccine 2–8 °C via predicate surface "storageTemperature"
Kapton approximately 400 °C in air via predicate surface "hasThermalStabilityUpTo"
Kapton up to about 260 °C via predicate surface "hasContinuousUseTemperature"
NIRCam cryogenic
MIRI around 7 kelvin
Fine Guidance Sensor approximately 40 kelvin via predicate surface "operationalTemperature"
VIS 100 pistol
surface form: VIS 100
military-standard environmental conditions via predicate surface "operatingTemperatureRange"
µA741 70 °C via predicate surface "hasMaximumOperatingTemperature"
µA741 0 °C via predicate surface "hasMinimumOperatingTemperature"
RAD750 −55 °C to +125 °C via predicate surface "operatingTemperatureRange"
RP-1 nearRoomTemperature via predicate surface "storageTemperature"
Svalbard Global Seed Vault approximately −18 °C via predicate surface "storageTemperature"
LHC insertion region for CMS cryogenic
Parker Solar Probe about 30 degrees Celsius behind heat shield via predicate surface "designOperatingTemperature"
Microchip ATSAMD21 -40 °C to 85 °C (typical industrial range) via predicate surface "operatingTemperatureRange"
Nordic nRF51822 -40 °C to +85 °C via predicate surface "hasOperatingTemperatureRange"
Ad26.COV2.S 2–8 °C via predicate surface "storageTemperature"
NICMOS cryocooler approximately 60–80 kelvin via predicate surface "targetTemperatureRange"
JWST Integrated Science Instrument Module approximately 40 kelvin to 50 kelvin for near-infrared instruments via predicate surface "operatingTemperatureRange"
JWST Integrated Science Instrument Module approximately 7 kelvin for MIRI via additional cooler via predicate surface "operatingTemperatureRange"
Low Frequency Instrument cryogenic
High Frequency Instrument 0.1 K
Large Space Simulator down to about -180 degrees Celsius via predicate surface "canReachTemperature"
Large Space Simulator up to about +120 degrees Celsius on illuminated surfaces via predicate surface "canReachTemperature"
ITER over 150 million degrees Celsius via predicate surface "designedPlasmaTemperature"
Prevnar 13 2-8 °C via predicate surface "storageTemperature"
Vaxzevria COVID-19 vaccine refrigerated 2–8 °C via predicate surface "storageTemperature"
Si(Li) detector liquid nitrogen temperature via predicate surface "typicallyCooledTo"
Si(Li) detector about 77 K via predicate surface "hasOperatingTemperature"
CUORE about 10 millikelvin
CRESST millikelvin temperatures via predicate surface "usesOperatingTemperature"
Westinghouse 3-loop PWR about 290 °C via predicate surface "coolantOperatingTemperatureInlet"
Mooney viscometer typically 100–200 °C via predicate surface "operatingTemperatureRange"
Haber–Bosch process typically 400–500 °C via predicate surface "operatingTemperatureRange"
Sulfolobus 70–80 °C via predicate surface "optimalTemperatureRange"
Sulfolobaceae 65–85 °C via predicate surface "optimalTemperatureRange"
Jcovden refrigerated conditions (2–8 °C) via predicate surface "storageTemperature"
Claus process 200–350 °C via predicate surface "catalyticStageTemperatureRange"
Magnox limited by Magnox cladding properties via predicate surface "operatingTemperatureLimit"
CPVC up to about 90 °C via predicate surface "hasTypicalServiceTemperatureLimit"
CPVC up to about 200 °F via predicate surface "hasTypicalServiceTemperatureLimit"