Westinghouse 3-loop PWR

E686612

The Westinghouse 3-loop PWR is a pressurized water reactor design featuring three primary coolant loops, widely used in commercial nuclear power plants for reliable electricity generation.

Jump to: Surface forms Statements Referenced by

Observed surface forms (2)

Surface form Occurrences
Westinghouse 4-loop PWR 1
Westinghouse PWR 1

Statements (48)

Predicate Object
instanceOf light water reactor design
pressurized water reactor design
application base-load power generation
chemicalShim dissolved boric acid in primary coolant
commercialUse electricity generation
containmentType large dry containment (typical)
controlRodMaterial boron carbide
silver-indium-cadmium alloy
coolantFlowConfiguration closed primary circuit with three loops
coolantOperatingTemperatureInlet about 290 °C
coolantOperatingTemperatureOutlet about 320 °C
corePowerDensity typical of commercial PWRs
designer Westinghouse Electric Company NERFINISHED
designGoal high availability
high reliability
robust safety margins
fuelType low-enriched uranium dioxide
generation Generation II
geographicDeployment Asia NERFINISHED
Europe NERFINISHED
United States NERFINISHED
moderatorType light water
neutronReflector water and structural materials
neutronSpectrum thermal
numberOfSteamGenerators 3
pressureBoundaryComponents pressurizer
reactor coolant loops
reactor pressure vessel
primaryCoolantLoops 3
primaryCoolantType light water
primarySystemPressure about 15.5 MPa
reactivityControlMethods burnable absorbers
control rods
soluble boron
reactorCoolantPumpsPerLoop 1
reactorCoolantPumpsTotal 3
safetySystems containment spray system
emergency core cooling system
residual heat removal system
safety injection system
secondarySideWorkingFluid water-steam
steamCycleType indirect steam cycle
steamGeneratorType vertical U-tube steam generator
thermalEfficiency around 32–34%
typicalElectricalOutputRange 800–1000 MWe
typicalFuelCycleLength 12–18 months
typicalFuelEnrichment up to about 4.5% U-235
typicalThermalPowerRange 2400–3000 MWt

Referenced by (3)

Full triples — surface form annotated when it differs from this entity's canonical label.

North Anna Nuclear Generating Station facilities reactorDesign Westinghouse 3-loop PWR
subject surface form: North Anna Nuclear Generating Station
Ascó Nuclear Power Plant reactorModel Westinghouse 3-loop PWR
this entity surface form: Westinghouse PWR
Salem Nuclear Power Plant reactorModel Westinghouse 3-loop PWR
this entity surface form: Westinghouse 4-loop PWR