IEC 60870‑5‑103
E790994
IEC 60870‑5‑103 is an international communication protocol standard used for telecontrol of protection equipment and substation control systems in electrical power networks.
All labels observed (1)
| Label | Occurrences |
|---|---|
| IEC 60870‑5‑103 canonical | 1 |
How this entity was disambiguated
This entity first appeared as the object of triple T9250158 — resolving that mention is where its identity was fixed. The disambiguator weighed these candidate entities and picked the highlighted one (or “None”, minting a new entity). This is how homonymy is resolved: the same surface form can point to different entities.
Target entity: IEC 60870‑5‑103 Context triple: [IEC 60870‑5‑101, relatedTo, IEC 60870‑5‑103]
-
A.
IEC 60870‑5‑101
IEC 60870‑5‑101 is an international standard defining basic telecontrol communication protocols for monitoring and controlling electrical power systems over serial links.
-
B.
IEC 60870‑5‑104
IEC 60870‑5‑104 is an international standard defining networked telecontrol communication protocols for supervisory control and data acquisition (SCADA) systems over TCP/IP in electrical power systems.
-
C.
IEC 60870
IEC 60870 is an international standard defining protocols for telecontrol and supervisory control and data acquisition (SCADA) systems in electrical power and industrial automation.
-
D.
IEC 61850
IEC 61850 is an international standard that defines communication protocols and data models for automation, protection, and control systems in electrical substations and power utility networks.
-
E.
IEC 61334
IEC 61334 is an international standard that defines protocols and requirements for low-speed power line communication used in utility and smart grid applications.
- F. None of above. chosen
- G. Unsure - the case is ambiguous/there is not enough information to decide.
Target entity: IEC 60870‑5‑103 Target entity description: IEC 60870‑5‑103 is an international communication protocol standard used for telecontrol of protection equipment and substation control systems in electrical power networks.
-
A.
IEC 60870‑5‑101
IEC 60870‑5‑101 is an international standard defining basic telecontrol communication protocols for monitoring and controlling electrical power systems over serial links.
-
B.
IEC 60870‑5‑104
IEC 60870‑5‑104 is an international standard defining networked telecontrol communication protocols for supervisory control and data acquisition (SCADA) systems over TCP/IP in electrical power systems.
-
C.
IEC 60870
IEC 60870 is an international standard defining protocols for telecontrol and supervisory control and data acquisition (SCADA) systems in electrical power and industrial automation.
-
D.
IEC 61850
IEC 61850 is an international standard that defines communication protocols and data models for automation, protection, and control systems in electrical substations and power utility networks.
-
E.
IEC 61334
IEC 61334 is an international standard that defines protocols and requirements for low-speed power line communication used in utility and smart grid applications.
- F. None of above. chosen
Statements (44)
| Predicate | Object |
|---|---|
| instanceOf |
IEC standard
ⓘ
communication protocol standard ⓘ telecontrol protocol ⓘ |
| alternativeTo | proprietary protection communication protocols ⓘ |
| appliesTo | electrical power networks ⓘ |
| category |
industrial communication protocol
ⓘ
power system communication standard ⓘ |
| communicationModel | master‑slave ⓘ |
| comparedTo | IEC 60870‑5‑101 NERFINISHED ⓘ |
| defines |
application layer for protection equipment communication
ⓘ
communication profile for protection equipment ⓘ data objects for protection and fault information ⓘ frame formats for protection equipment telecontrol ⓘ |
| differenceFrom | IEC 60870‑5‑101 is oriented to general telecontrol, while IEC 60870‑5‑103 is oriented to protection equipment ⓘ |
| field |
electric power systems
ⓘ
power system protection ⓘ substation automation ⓘ |
| focus |
fault and disturbance information
ⓘ
protection‑related data exchange ⓘ |
| goal |
interoperability between protection devices and control systems
ⓘ
standardized exchange of protection information ⓘ |
| includes |
addressing scheme for protection devices
ⓘ
mechanisms for disturbance record transfer ⓘ mechanisms for event and alarm reporting ⓘ time tagging of events ⓘ |
| OSIReference |
application layer
ⓘ
link layer ⓘ |
| partOf | IEC 60870‑5 series NERFINISHED ⓘ |
| physicalLayer | serial communication ⓘ |
| publishedBy | International Electrotechnical Commission NERFINISHED ⓘ |
| supports |
cyclic and spontaneous data transmission
ⓘ
event transmission from protection devices ⓘ fault record transmission ⓘ remote parameterization of protection equipment ⓘ time synchronization of protection devices ⓘ |
| typicalMasterDevice | substation control system GENERATED ⓘ |
| typicalPhysicalMedium |
RS‑232
GENERATED
ⓘ
RS‑485 GENERATED ⓘ |
| typicalSlaveDevice | protection relay GENERATED ⓘ |
| use |
communication between protection relays and control systems
ⓘ
substation control systems communication ⓘ telecontrol of protection equipment ⓘ |
| usedIn |
substation protection systems
ⓘ
transmission and distribution substations ⓘ |
How these facts were elicited
The pipeline generated the facts above by prompting gpt-5.1 with this entity's name + description and the instruction below.
You are a knowledge base construction expert. Given a subject entity and a description of it, return factual statements that you know for the subject as a JSON list of dictionaries(triples), where keys must be "subject", "predicate" and "object". The number of facts may be very high, between 25 to 50 or more, for very popular subjects. For less popular subjects, the number of facts can be very low, like 5 or 10. # Requirements - If you don't know the subject at all, return an empty list. - If the subject is not a named entity, return an empty list. - Include at least one triple where predicate is "instanceOf". - Do not get too wordy. - Separate several objects into multiple triples with one object.
Subject: IEC 60870‑5‑103 Description of subject: IEC 60870‑5‑103 is an international communication protocol standard used for telecontrol of protection equipment and substation control systems in electrical power networks.
Referenced by (1)
Full triples — surface form annotated when it differs from this entity's canonical label.