AP1000

E410578

The AP1000 is a Generation III+ pressurized water nuclear reactor design developed by Westinghouse that emphasizes passive safety systems and modular construction.

All labels observed (1)

Label Occurrences
AP1000 canonical 2

How this entity was disambiguated

Statements (50)

Predicate Object
instanceOf Generation III+ nuclear reactor
pressurized water reactor design
activeSafetySystemReduction reduced number of active safety components
constructionMethod modular construction
prefabricated modules
containmentFeature concrete shield building
containmentType steel containment vessel
coolant light water
coolingSystem natural circulation in passive systems
countryOfFirstDeployment China
designCertificationYear 2011
designFeature modular construction
designGoal enhanced safety
reduced construction cost
reduced construction time
simplified plant layout
designLifetime 60 years
designSimplification reduced control cables
reduced length of piping
reduced number of pumps
reduced number of valves
developer Westinghouse Electric Corporation
surface form: Westinghouse Electric Company
electricPowerOutput approximately 1110 MWe
examplePlant Haiyang Nuclear Power Plant Unit 1
Sanmen Nuclear Power Station Unit 1
Vogtle Electric Generating Plant
surface form: Vogtle Electric Generating Plant Unit 3

Vogtle Electric Generating Plant
surface form: Vogtle Electric Generating Plant Unit 4
fuelAssemblyType 17x17 PWR fuel assembly
fuelForm uranium dioxide fuel pellets
fuelType low-enriched uranium
gracePeriodDuration at least 72 hours without AC power
moderator light water
netEfficiency about 33 percent
primaryCircuit two-loop configuration
reactorType pressurized water reactor
regulator U.S. Nuclear Regulatory Commission
surface form: United States Nuclear Regulatory Commission
regulatoryApproval U.S. NRC design certification
safetyFeature passive safety systems
safetyObjective mitigation of severe accidents without core damage
reduced probability of large radioactive releases
safetyPhilosophy defense in depth
grace period without operator action
safetySystemType automatic depressurization system
in-containment refueling water storage tank
passive containment cooling system
passive core cooling system
passive residual heat removal system
steamGeneratorType vertical U-tube steam generators
targetMarket international nuclear power market
thermalPower approximately 3400 MWth

How these facts were elicited

Referenced by (2)

Full triples — surface form annotated when it differs from this entity's canonical label.

Vogtle Electric Generating Plant reactorDesign AP1000
subject surface form: Vogtle Unit 3
Vogtle Electric Generating Plant reactorDesign AP1000
subject surface form: Vogtle Unit 4